  格力(li)空(kong)调(diao)(diao)自上(shang)个世纪90年代进入中(zhong)(zhong)央(yang)空(kong)调(diao)(diao)市场以来,就一(yi)直引领(ling)着国内市场中(zhong)(zhong)央(yang)空(kong)调(diao)(diao)的(de)发(fa)展(zhan),当然,它除了家用(yong)(yong)(yong)空(kong)调(diao)(diao)普及率较(jiao)高,其近年来大肆(si)发(fa)力(li)的(de)中(zhong)(zhong)央(yang)空(kong)调(diao)(diao),更是(shi)应用(yong)(yong)(yong)广泛,在(zai)不同场所安(an)装使(shi)用(yong)(yong)(yong)。不过,中(zhong)(zhong)央(yang)空(kong)调(diao)(diao)也和家用(yong)(yong)(yong)空(kong)调(diao)(diao)一(yi)样,使(shi)用(yong)(yong)(yong)过程(cheng)中(zhong)(zhong)难免会出现故障(zhang)或是(shi)使(shi)用(yong)(yong)(yong)难题(ti),那么,如(ru)果(guo)使(shi)用(yong)(yong)(yong)的(de)是(shi)格力(li)的(de)中(zhong)(zhong)央(yang)空(kong)调(diao)(diao),我们如(ru)何区分它的(de)故障(zhang)代码(ma)是(shi)何意(yi)?

  今天,笔者就(jiu)简单(dan)的(de)整(zheng)理下(xia),格(ge)力中央空调(diao)故(gu)障(zhang)代码所(suo)代表的(de)故(gu)障(zhang)类型(xing),感兴(xing)趣的(de)朋(peng)友(you),不妨了(le)解下(xia)。

  394系统1电(dian)源缺(逆)相或者系统1内部保护缺相压缩机(ji)保护一螺杆式风冷冷(热)水(shui)机(ji)组

  395系统2电源缺(逆)相或者系统2内部保护(hu)缺相压缩(suo)机保护(hu)二螺杆式风冷(leng)冷(leng)(热)水机组

  460压缩(suo)(suo)机一(yi)/二启(qi)动时低压过低压缩(suo)(suo)机一(yi)/二启(qi)动低压保护螺杆式水(shui)冷冷水(shui)机组

  461压(ya)缩机一/二(er)启动(dong)后接触器不吸(xi)合压(ya)缩机一/二(er)接触器吸(xi)合故障(zhang)螺杆式水(shui)冷冷水(shui)机组

  462压缩机一/二(er)停机后接(jie)触器粘连(lian)压缩机一/二(er)接(jie)触器粘连(lian)保(bao)护螺(luo)杆式水冷冷水机组

  493系(xi)统1高低(油(you)压(ya)差(cha)保护(hu))系(xi)统一高低(油(you)压(ya)差(cha)保护(hu))螺杆水(shui)冷冷水(shui)前期机组(zu)

  494系(xi)统(tong)(tong)2高低(油压差保(bao)护(hu))系(xi)统(tong)(tong)二高低(油压差保(bao)护(hu))螺杆(gan)水冷冷水前期(qi)机组(zu)

  516防冻(dong)温度传感(gan)(gan)器(qi)1保护防冻(dong)温感(gan)(gan)器(qi)或防冻(dong)/防过热(re)温感(gan)(gan)器(qi)模块式风冷冷(热(re))水(shui)机(ji)组(zu)

  517防冻温度(du)传(chuan)感(gan)器(qi)2保护/环境温度(du)传(chuan)感(gan)器(qi)保护参考点(dian)温感(gan)器(qi)模(mo)块式风冷冷(热)水机组

  561系(xi)统一(yi)压(ya)缩(suo)机运行后其排(pai)气(qi)温(wen)度在特定时间内,未达(da)到正常(chang)温(wen)度排(pai)气(qi)温(wen)感(gan)器一(yi)失灵模块式风冷冷(热)水(shui)机组

  562系统二压(ya)缩机(ji)运(yun)行后(hou)其排(pai)气(qi)温度(du)在特定时间内,未(wei)达到(dao)正常温度(du)排(pai)气(qi)温感器(qi)二失灵模块式风冷(leng)(leng)冷(leng)(leng)(热(re))水机(ji)组

  567系统一制冷节(jie)流点温(wen)感(gan)器(qi)(qi)故(gu)障(zhang)节(jie)流阀一温(wen)感(gan)器(qi)(qi)故(gu)障(zhang)模块式风冷冷(热)水机组

  568系统(tong)二制冷节(jie)流点温(wen)(wen)感器故障(zhang)节(jie)流阀二温(wen)(wen)感器故障(zhang)模块式(shi)风冷冷(热)水机组

  572系(xi)统一压缩(suo)机(ji)二(er)运(yun)行后其(qi)排气(qi)温(wen)度在特定(ding)时间(jian)内(nei),未达到正常(chang)温(wen)度系(xi)统一排气(qi)二(er)失灵模块式风(feng)冷(leng)(leng)冷(leng)(leng)(热)水机(ji)组

  574系(xi)统(tong)二(er)压(ya)缩机(ji)二(er)运(yun)行后其排(pai)气温度在(zai)特定时间内,未达到正(zheng)常(chang)温度系(xi)统(tong)二(er)排(pai)气二(er)失灵(ling)模块式风(feng)冷冷(热)水(shui)机(ji)组(zu)

  575系统一(yi)(yi)压(ya)缩(suo)机一(yi)(yi)运行后其排气(qi)温度在特(te)定时间内,未达到正常温度系统一(yi)(yi)排气(qi)一(yi)(yi)失灵模块式风冷(leng)冷(leng)(热)水机组

  576系(xi)统二压缩机(ji)一(yi)运行后其(qi)排气温度(du)在特定(ding)时间内(nei),未达到正(zheng)常(chang)温度(du)系(xi)统二排气一(yi)失灵模块式风(feng)冷冷(热)水(shui)机(ji)组

  582系统一(yi)制冷节流点(dian)温感器(qi)故障节流阀一(yi)温感器(qi)故障模块式风冷冷(热)水机组

  583系(xi)统二制冷节(jie)流点温(wen)感器(qi)故障节(jie)流阀二温(wen)感器(qi)故障模块(kuai)式风冷冷(热(re))水机组

  586系统一(yi)压(ya)缩机运行后(hou)其排(pai)气温(wen)(wen)度在特(te)定时间内(nei),未达到正常(chang)温(wen)(wen)度排(pai)气温(wen)(wen)感器一(yi)失(shi)灵(ling)模块式风冷冷(热)水(shui)机组

  587系统(tong)二(er)压(ya)缩机(ji)运行后其排(pai)气温度(du)在特定时间内,未达到正常温度(du)排(pai)气温感器二(er)失灵模块(kuai)式风冷冷(热)水机(ji)组

  592系统一用户(hu)侧(ce)出水(shui)(shui)(shui)温(wen)感(gan)器(qi)故(gu)障用户(hu)侧(ce)出水(shui)(shui)(shui)温(wen)感(gan)器(qi)一模(mo)块式风(feng)冷冷(热)水(shui)(shui)(shui)机组(zu)

  593系统二(er)用户侧出水温感(gan)器故障(zhang)用户侧出水温感(gan)器二(er)模块式风冷(leng)冷(leng)(热)水机(ji)组

  595系统(tong)一(yi)热(re)源(yuan)侧(ce)出水(shui)(shui)温(wen)感(gan)(gan)器故障热(re)源(yuan)侧(ce)出水(shui)(shui)温(wen)感(gan)(gan)器一(yi)模块式风冷冷(热(re))水(shui)(shui)机组

  596系统二(er)热(re)源侧出水温感器故障热(re)源侧出水温感器二(er)模块式风冷(leng)冷(leng)(热(re))水机组

  597系(xi)统一(yi)制(zhi)冷(leng)节流点(dian)温感器故障(zhang)制(zhi)冷(leng)节流阀一(yi)温感器模块式风冷(leng)冷(leng)(热)水机组

  598系统二(er)制冷(leng)(leng)节流点温感(gan)器故障制冷(leng)(leng)节流阀二(er)温感(gan)器模块式风冷(leng)(leng)冷(leng)(leng)(热(re))水机组

  599系统一制热节(jie)流点(dian)温感器故障制热节(jie)流阀一温感器模块(kuai)式风冷冷(热)水机组

  600系统二制(zhi)热(re)节流点(dian)温感器故(gu)障制(zhi)热(re)节流阀二温感器模块式风冷冷(热(re))水机组(zu)

  602水(shui)泵开(kai)启(qi)30秒后(hou),连续10秒内检测到水(shui)流开(kai)关断开(kai)水(shui)流开(kai)关故障模块式风冷(leng)(leng)冷(leng)(leng)(热)水(shui)机组(zu)

  603连续(xu)30秒内检(jian)测到(dao)热(re)水(shui)(shui)(shui)侧进水(shui)(shui)(shui)温度大于80度热(re)水(shui)(shui)(shui)侧防过(guo)热(re)保护模块式风冷冷(热(re))水(shui)(shui)(shui)机组

  606蒸(zheng)气罐(guan)内水(shui)(shui)(shui)垢较多或者排(pai)水(shui)(shui)(shui)系统故(gu)障(排(pai)水(shui)(shui)(shui)阀坏、排(pai)水(shui)(shui)(shui)管(guan)堵)排(pai)水(shui)(shui)(shui)故(gu)障恒温恒湿机(ji)

  607内(nei):内(nei)风(feng)(feng)机过电流。外:变频风(feng)(feng)机保护故障(zhang);外风(feng)(feng)机通(tong)信故障(zhang)风(feng)(feng)机故障(zhang)恒温(wen)恒湿机

网站飞火游戏平台| 关于我们|飞火游戏平台|产品中心|业务类型|合作案例|招聘启事|联系我们|

Copyright © 2002-2020 陕西丰运制冷设备有限公司 版权所有
电话:400-765-0018 地址:西安市莲湖区龙首北路西段118号 网站地图

热门关键词: 飞火游戏平台   冷库维修    中央飞火游戏平台    西安中央飞火游戏平台    制冷设备维修    中央空调保养  
中央空调安装公司   中央空调改造   空调清洗保养   冷库设计安装   冷却塔维修保养   空调移机  
中央飞火游戏平台多少钱   中央飞火游戏平台哪家好   飞火游戏平台电话   飞火游戏平台公司  
免责声明:网站部分内容为转载或编者观点,不代表本站意见,不承担任何法律责任、如侵权请联系删除。

  • 电话咨询

  • 400-765-0018
var _hmt = _hmt || []; (function() { var hm = document.createElement("script"); hm.src = "https://hm.baidu.com/hm.js?78ebdacae9da971faf025645ab77d367"; var s = document.getElementsByTagName("script")[0]; s.parentNode.insertBefore(hm, s); })(); cps测试 网上森林舞会 捕鱼游戏网络版 yy游戏大厅